Product Brand | Model Name | Add To Compare |
Dell Technologies | PowerEdge R760 | |
Dell Technologies | PowerEdge R240 | |
Dell Technologies | PowerEdge R340 | |
Dell Technologies | PowerEdge R740xd2 | |
Dell Technologies | PowerEdge R940xa | |
Dell Technologies | PowerEdge R440 | |
Dell Technologies | PowerEdge R540 | |
Dell Technologies | PowerEdge R640 | |
Dell Technologies | PowerEdge R740 | |
Dell Technologies | PowerEdge R740xd | |
Dell Technologies | PowerEdge R940 | |
Dell Technologies | PowerEdge R650 | |
Dell Technologies | PowerEdge R750 | |
Dell Technologies | PowerEdge R350 | |
Dell Technologies | PowerEdge R550 | |
Dell Technologies | PowerEdge R450 | |
Dell Technologies | PowerEdge R660 |
* Select up to 3 products other than a base product
Processor | Up to two 4th Generation Intel Xeon Scalable processor with up to 56 cores per processor and with optional Intel® QuickAssist Technology |
---|---|
Memory | • 32 DDR5 DIMM slots, supports RDIMM 8 TB max, speeds up to 4800 MT/s • Supports registered ECC DDR5 DIMMs only |
Storage Controllers | • Internal Boot: Boot Optimized Storage Subsystem (BOSS-N1): HWRAID 2 x M.2 NVMe SSDs or USB • External HBA (non-RAID): HBA355e • Software RAID: S160 |
Drive Bays | Front bays: • Up to 12 x 3.5-inch SAS/SATA (HDD/SSD) max 240 TB • Up to 8 x 2.5-inch SAS/SATA/NVMe (HDD/SSD) max 122.88 TB • Up to 16 x 2.5-inch SAS/SATA/NVMe (HDD/SSD) max 245.76 TB • Up to 24 x 2.5-inch SAS/SATA/NVMe (HDD/SSD) max 368.64 TB Rear bays: • Up to 2 x 2.5-inch SAS/SATA/NVMe (HDD/SSD) max 30.72 TB • Up to 4 x 2.5-inch SAS/SATA/NVMe (HDD/SSD) max 61.44 TB |
Power Supplies | • 2800 W Titanium 200—240 VAC or 240 HVDC, hot swap redundant • 2400 W Platinum 100—240 VAC or 240 HVDC, hot swap redundant • 1800 W Titanium 200—240 VAC or 240 HVDC, hot swap redundant • 1400 W Platinum 100—240 VAC or 240 HVDC, hot swap redundant • 1100 W Titanium 100—240 VAC or 240 HVDC, hot swap redundant • 1100 W LVDC -48 — -60 VDC, hot swap redundant • 800 W Platinum 100—240 VAC or 240 HVDC, hot swap redundant • 700 W Titanium 200—240 VAC or 240 HVDC, hot swap redundant |
NIC | • 2 x 1 GbE LOM card (optional) |
GPU | Up to 2 x 350 W DW and 6 x 75 W SW Up to eight PCIe slots: • Slot 1: 1 x8 Gen5 or 1 x8/1 x16 Gen4 Full height, Half length or 1 x16 Gen4 Full height, Full length • Slot 2: 1 x8/1 x16 Gen5 or 1 x8 Gen4 Full height, Half length or 1 x16 Gen5 Full height, Full length • Slot 3: 1 x16 Gen4 Low profile, Half length • Slot 4: 1 x8 Gen4 Full height, Half length • Slot 5: 1 x8/1 x16 Gen4 Full height, Half length or 1 x16 Gen4 Full height, Full length • Slot 6: 1 x16 Gen4 Low profile, Half length • Slot 7: 1 x8/1 x16 Gen5 or 1 x8 Gen4 Full height, Half length • Slot 7 SNAPI: 1 x16 Gen5 Full height, Half length • Slot 8: 1 x8 Gen5 or 1 x8 Gen4 Full height, Half length |
Form Factor | 2U Rack |